multiple electrical issues

12 messages,  Last post on Oct 09, 2011 at 5:13 PM

You are in the Chevrolet Silverado & GMC Sierra Forum.

What is this discussion about? Chevrolet Silverado 1500, GMC Sierra 1500, Chevrolet Silverado 2500, Truck

#4 of 12 Re: multiple electrical issues [rhance] by gmcustsvc

Jun 29, 2011 (1:26 pm)

Replying to: rhance (Jun 28, 2011 4:43 pm)
rhance,
 
Thank you for the update. Please keep me posted with any information from the dealership. I completely understand, 103 is hot to be without an A/C!
 
Thank you,
Caron, GM Customer Service

#5 of 12 Re: multiple electrical issues [gmcustsvc] by rhance

Jun 29, 2011 (6:18 pm)

Replying to: gmcustsvc (Jun 29, 2011 1:26 pm)
Odd drive from office. Started up and the hvac blower fan and all of the other weird inop components were working as well. Can't have this happening if your job is in outside sales and taking clients to lunch or the golf course. Still going into dealership with the thought they can find an intermittant problem like this. Being a few months and miles out of the basic warranty, I'm in hopes that GM will foot this bill as it has been an ongoing
complaint from the previous owner with documentation at another GM store.

#6 of 12 Re: multiple electrical issues [rhance] by gmcustsvc

Jul 01, 2011 (11:54 am)

Replying to: rhance (Jun 29, 2011 6:18 pm)
rhance,
 
I completely understand. Please keep me updated on any information from the dealership.
 
Thank you,
Caron, GM Customer Service

#7 of 12 Re: multiple electrical issues [gmcustsvc] by rhance

Jul 04, 2011 (11:46 am)

Replying to: gmcustsvc (Jul 01, 2011 11:54 am)
Left at dealership for two days with the Hvac blower inop. S/A said they couldn't pinpoint problem and wanted me to drive in when it reoccurs. It's odd that when it does quit I can disconnect the blower motor connector from the blower module for approx 10-15 mins and reconnect and blower works for several days. I can disconnect blower and apply 12 volts and it works fine. I believe problem to be a ground or circuit issue with control module be it the blower or Hvac control head itself. The event is more consistant when temps above 90. I really believe the svc tech didn't do any more than I can do. They did't charge me but I just want it fixed. Maybe they can find it the next visit. Any suggestion from your end would be greatly appreciated.

#8 of 12 Re: multiple electrical issues [rhance] by gmcustsvc

Jul 05, 2011 (1:38 pm)

Replying to: rhance (Jul 04, 2011 11:46 am)
rhance,
I would recommend asking the dealer to involve technical assistance. Have they been able to diagnosis the vehicle and concern? I look forward to your response.
Christina
GM Customer Service

#9 of 12 Re: multiple electrical issues [gmcustsvc] by rhance

Jul 05, 2011 (5:35 pm)

Replying to: gmcustsvc (Jul 05, 2011 1:38 pm)
I will ask for technical assistance. They were reluctant to even have a conversation about the repair when I mentioned some "goodwill" consideration since it's out of warranty by a few months and miles. S/A "drove" pickup for approx 1 mile to verify blower not working. I drove it to them not working! As for your answer, no they haven't diagnosed the problem or even offered to try anything to my knowledge, such as swapping a "known good" component for a few days. What ever the problem it is intermittant and will require further head scratching and for someone to make a decision which way to go. Once again I'll keep you posted. Did quit over the weekend but tech not at dealership.

#10 of 12 Re: multiple electrical issues [rhance] by gmcustsvc

Jul 07, 2011 (2:12 pm)

Replying to: rhance (Jul 05, 2011 5:35 pm)
rhance,
Since the problem is intermittent I would ask them to install a recorder to help them diagnosis the concerns. I would also like to set up a case for you with GM Customer Assistance since your vehicle is so close to the warranty date. This will also report your concerns to GM and an agent will continually check up with your dealer. Please email me with your VIN, current mileage, involved dealer, and complete contact information. I look forward to your response.
Christina
GM Customer Service

#11 of 12 YOUR REQUESTED INFO-KCRAM by rhance

Jul 08, 2011 (9:59 am)

VIN 2GCEK13M871537816, 39987 MILES. WILL SHOW TO BE REGISTERED TO JACK CLAYTON WHO IS MY DECEASED GRANDFATHER WHOM I INHERITED THE TRUCK FROM. REPAIR ORDER FROM PLAINS CHEVROLET IN AMARILLO TX IS 354041. THIS ISSUE HAS BEEN ADDRESSED AT THE SELLING DEALER IN CLOVIS NM-BENDER CHEVROLET ALSO WITHIN THE 1ST OR 2ND YEAR.

#12 of 12 Multiple electrical issues by rhance

Oct 09, 2011 (5:13 pm)

Well after lots of head scratching and troubleshooting the problem has been solved and I hope no one else has to go through the same headache.The evaporator drain was blocked, not allowing the condensation to drain. Somewhere inside the dash one or more connectors
would get wet from the condensation sloshing in the evap case and short or cause feedback
in several circuits. I've back flushed the evap drain from underneath and lots of crap came out. Drain has work flawlessly and the strange phenomenon has been eliminated. Even the dealer had no ideas and mine was just luck in noticing water filling the right floor. Hope this will help someone in the future. Thanks for the help.