Sign In Join 



Ford Crown Victoria/Mercury Grand Marquis Climate Control

37 messages,  Last post on Nov 07, 2009 at 10:20 PM

You are in the Ford Crown Victoria/Mercury Grand Marquis Forum. Your Hosts are pat & karens

What is this discussion about? Ford Crown Victoria, Mercury Grand Marquis, Heating / Cooling, Sedan


Messages Page 2 of 5
1
2
3
4
5
Prev
Next
Last
Go To Msg #
Search This Discussion

#5 of 37
Re: Bubble, bubble [p2min] by euphonium
Jun 22, 2006 (7:51 pm)
Reply

Replying to: p2min (Jun 22, 2006 2:15 pm)

Yep, after you unscrew the top - fill it to the line leaving a little room at the top for possible overflow. The coolant is anti freeze 50% and H2O 50%. The H2O evaporates in time requiring the overflow container to have water added.
#6 of 37
Re: Bubble, bubble [euphonium] by p2min
Jun 27, 2006 (1:48 pm)
Reply

Replying to: euphonium (Jun 22, 2006 7:51 pm)

Thanks. I changed the thermostat in this car yesterday, filled it with the 50/50 mixture and it drove cool. However, when I stopped and started again I had puddle of fluid directly under the car, but not near the radiator. What could this be?
#7 of 37
Re: Bubble, bubble [p2min] by euphonium
Jun 28, 2006 (12:55 pm)
Reply

Replying to: p2min (Jun 27, 2006 1:48 pm)

Marsha is correct if the fluid color is same as coolant.
 
If the fluid on the floor is clear, it is probably condensation from the A/C system, which is normal.
#9 of 37
Fan has mind of its own by vmon
Jun 26, 2006 (7:03 am)
Reply
I have a 2003 CVLX. The fan will not blow air from vent. It changes between floor and defrost for unknown reasons. it does not matter if it is heat or AC. It switches with notice or any action on my part. Has anyone experienced this?
 
vmon
#10 of 37
Cheap & Easy Fix for EATC Blower Operation Problem by mr5x5
Mar 21, 2007 (12:14 pm)
Reply
I have been searching the Forums on www.crownvic.net and fiddling around with the EATC System Blower Motor Controller circuit on our 2001 GM LS for a year trying to solve the (initially) intermittent operation of the Blower for a year. After running with the Blower hot-wired thru a toggle switch for six months (when the intermittent problem went to complete failure)I finally got around to pulling the Controller Board out of the Heater/AC box last week.
On my last search of the www.crownvic.net Forums I turned-up a note from a fellow who said "[i]most guys just fix it with a little bit of solder[/i]" this turned-on a lightbulb for me and today I had a look at the solder-joints where the connector is attached to the Controller Board. Sure enough, I could see that the solder was cracked at one of the big lugs of the connector!
I heated-up the pins at all 5 connector lugs and flowed a little solder into the "gaps" around the pins. When I plugged the Board into the harness I found I have a Blower that once again works under control of the EATC!
Now all I have to do is re-install the Board into the Heater/AC Box - a real tight squeeze. Right now I have it tie-wrapped to something under the hood but the heat sink on the Power Transistor gets REAL HOT - I think the best place in it is back inside that Heater/AC Box...
#11 of 37
blower mower controller by jsylvester
Mar 22, 2007 (6:16 pm)
Reply
Mine went out as well a couple of weeks ago on my 2002 Grand Marquis. I think it did the same thing yours did, as my mechanic said it was not burned, it just quit working.
 
This should make you feel better - it cost me $145 to have my mechanic fix it, including parts.
#12 of 37
2001 EATC Board by dillansdaddy
Apr 01, 2007 (1:01 pm)
Reply
I read that you can check your Connectors and possibly Solder to fix the Blower problem. Where might I find the Heater/AC Box so I can access it and see if I have the same connector problem?
#13 of 37
Re: Fan has mind of its own [vmon] by cabinetpro
Apr 14, 2007 (10:44 am)
Reply

Replying to: vmon (Jun 26, 2006 8:03 am)

I had this problem on my Marauder. Try unplugging the vacuum plugs at the passenger side behind the oil and volt meter. then take a jumper vacuum hose (starting with stub that has vacuum in it, with the car running) and plug it into different stubs and see if the blendoors change, (the air will come out of the defrost or vents). If it does, then the climate controller is bad. New at the dealer about $500.00. used on Ebay about $50.00.
 
This fixed my air problem.
 
Good luck.
Brian
#14 of 37
2003 Mercury Grand Marquis LSE Heater & A/C motor NOT Blowing by ascorbate
May 25, 2007 (10:35 am)
Reply
I have read thru another post in this forum about heater and a/c blower motors that stopped working suddenly.
 
I have a similar problem with a 2003 Mercury Grand Marquis LSE with climate control (Electronic Automatic Temperature Control or EATC for short). I have checked the obvious including the inside passenger compartment fuses plus the power distribution box underneath the front hood with particular attention to both the blower motor relay and blower motor fuses. I even swapped them out with other working relay and fuses in the power distribution box. I then measured the voltage being applied to the blower motor itself under the hood. It read anywhere from 1 to 6 DC volts or so. I have a similar blower motor layout in a well maintained 1997 Ford Crown Victoria (without EATC) and that voltage reading was 13-14 volts whether the fan speed control was set on low or high. So I'm suspicious of the lower voltage I measured in my Grand Marquis versus my Crown Vic... why would there be this big difference?
 
While traveling down the highway yesterday at 50-60 mph with the a/c set to 70 degrees, I could feel cool air coming from the vents in my 2003 Grand Marquis probably because of some of the air being recirculated from the outside to the inside. The faster I went, the more cool air I could feel coming from the vents BUT still the blower motor wasn't working. So the A/C system is working, it just ain't blowing this cool air around the inside of my car!
 
I read about a EATC module self test today at: http://www.p71interceptor.com/eatcswap/selftest.html which I performed with NO Diagnostic Trouble Codes (DTC) indicated. I then disassembled the fan speed control switch, cleaned it with a cotton swab and some rubbing alcohol, reassembled everything but still the same result... the heater and a/c is not blowing any warm or cold air whatsoever.
 
What else am I overlooking?

Messages Page 2 of 5
1
2
3
4
5
Prev
Next
Last
Go To Msg #
Search This Discussion
To POST a message, please Sign In.

New? Join Now!

Forum Tools

Please sign in.
Email Address:

Password:

Forgot Password?

Search Forums

Enter Keyword(s)

Advanced Search

Browse by Vehicle



View All Vehicles
Advertisement
Ask the Community
See What People Are Asking

Browse by Board

Browse by Topic


View All Topics

Today's Chats

Advertisement